AC/DC Solar Surface Pump
AC/DCSurface Pump

AC/DC Solar Surface Pump

40 mMax head
60 m³/hMax flow
600–2200 WPower range
2 yrWarranty
2-yr Warranty70+ countries15+ years experience✓ CE · RoHS · ISO

Engineering note. Maximum head and maximum flow are curve endpoints, not one simultaneous duty point. Final selection is verified against your total head, required flow and solar resource.

  • Permanent-magnet brushless motor + intelligent MPPT (auto start/stop, soft-start)
  • Controller LED display: voltage / current / power / speed (RPM) / error code
  • Air cooling
  • Full protection: over/under-voltage, overload, over-current, dry-run, reverse, over-temp
  • Runs directly off PV modules — no batteries required
  • Cast-iron / SUS304 wetted parts (SUS316 optional for corrosive water)

Performance Curves (Q–H)

Head–flow curve of every model in this series — exact data from our engineering datasheets.

Hover or tap a curve / model code to inspect it
0020840166024803210040Max flow (m³/h)Max head (m)

Specifications

#ModelVoltage (V)Power (W)Current (A)Max flow (m³/h)Max head (m)OutletØ (mm)Length (mm)Weight (kg)Recommended cable (mm²)Recommended PV
1PHF15-14-72-600-H726008.315141.5"×1.5"3759.92.53 × 300 Wp
2PSGJ3.1-35-72-600-H726008.33.1351.0"×1.0"3759.92.53 × 300 Wp
3PHF20-14-96-750-H967507.820142.0"×2.0"39010.92.53 × 300 Wp
4PSGJ3.1-40-96-750-H967507.83.1401.0"×1.0"39010.92.53 × 300 Wp
5PZSU17-14-144-1100-H14411007.617142.0"×2.0"42013.12.56 × 300 Wp
6PHF28-15-144-1100-H14411007.628152.0"×2.0"42013.12.56 × 300 Wp
7PHF45-17-192-1500-H19215007.845173.0"×3.0"45515.82.58 × 300 Wp
8PZSU18-22-192-1500-H19215007.818222.0"×2.0"45515.82.58 × 300 Wp
9PHF60-16-280-2200-H28022007.960164.0"×4.0"52020.32.510 × 300 Wp
10PZSU45-19-280-2200-H28022007.945193.0"×3.0"52020.32.510 × 300 Wp

Motor & Drive

MotorPermanent-magnet DC brushless (PMSM)
DriveSensorless FOC, pure sine-wave output
MPPT tracking>99%
Insulation classF (155 °C)
DutyS1 (continuous)
Ingress protectionIP55 / IP66
Warranty2 years

Controller & Protections

ControllerSensorless FOC sine-wave vector drive + MPPT (>99%), LED display
DisplayVoltage, Current, Power, Speed (RPM), Speed adjustment, Error code
Controller size360 × 260 × 140 mm
Protections
OverloadOver-currentUnder-loadUnder-voltageReverse-connectionOver-temperature (thermal)Dry-run / low-waterSoft-start
Remote monitoring (optional): Optional 4G/GSM or Wi-Fi monitoring module — remote flow, water level, energy and fault alerts with OTA updates (add-on; the standard controller uses a local LED display).

Operating conditions

Water temperature0–40 °C
Sand content≤ 0.05 % (≤ 500 g/m³)
pH range5–9
Ambient temperature-15 to 70 °C

Materials

  • StandardCast-iron (HT200) body + SUS304 / brass impeller + SUS304 shaft (Cast iron for durability; aluminium body available for portability)
  • Corrosion (option)SUS304 / SUS316 body & impeller

Premium components

  • 100% copper motor windings
  • Class F (155 °C) insulation system
  • NSK-grade sealed ball bearings
  • SUS304 shaft + cast-iron / stainless hydraulics
  • Silicon-carbide / ceramic mechanical seal
  • Efficient motor cooling
  • PMSM + sensorless FOC sine-wave controller, MPPT >99%

Recommended cable

PV-to-controller & motor cable 2.5 mm² by model (copper, sized for a ~50 m run; step up one size per additional ~50 m of drop).

Per-model cable cross-section is listed in the specification table above (mm² column).

Certifications

RoHSCBTUVSGSISO 9001ISO 14001
Standards
IEC 62253 (PV pumping systems)IEC 60034 (rotating machines)IEC 60529 (enclosure / IP)

Frequently asked questions

What power and voltage options does the AC/DC Solar Surface Pump come in?

The AC/DC Solar Surface Pump range covers 10 models from 600 W to 2200 W, with system voltages of 72 / 96 / 144 / 192 / 280 V.

What maximum head and flow can the AC/DC Solar Surface Pump reach?

Top models reach up to 40 m maximum head and up to 60 m³/h maximum flow. These are curve endpoints, not one simultaneous duty point — the exact model is selected against your required head, flow and solar resource.

Does the AC/DC Solar Surface Pump need batteries to run on solar power?

No. It runs directly off PV modules through an MPPT controller (>99% tracking efficiency), and as an AC/DC hybrid it can also run from 220 V AC mains (90–240 V, 50/60 Hz) or a generator via an external transfer switch — no battery bank required.

Is the AC/DC Solar Surface Pump protected against dry running?

Yes. Built-in protections include Overload, Over-current, Under-load, Under-voltage, Reverse-connection, Over-temperature (thermal), Dry-run / low-water, Soft-start. The pump motor is rated IP55 and the controller is rated IP66.

What water conditions can the AC/DC Solar Surface Pump handle?

It is rated for water temperatures of 0–40 °C, sand content ≤ 0.05 % (≤ 500 g/m³) and pH 5–9.

Surface Pump